| 1 | OXYGEN | Check |
| | Turn OXYGEN switch ON and check for airflow. |
| | Turn OXYGEN switch OFF and check that airflow ceases. |
| 2 | VENT AIRFLOW thumbwheel | OFF |
| 3 | SYS TEST - SYS PWR ground check panel | Closed |
| 4 | KY-28 or KY-58 | P/OFF |
| 5 | ICS panel | Set |
| | - VOL knob - Set. |
| | - Amplifier - NORM. |
| | - Function selector - COLD MIC. |
| 6 | TACAN function selector | OFF |
| 7 | U/VHF MODE selector | OFF |
| 8 | LIQ COOLING switch | OFF |
| 9 | EJECT CMD lever | Set according to squadron policy. |
| 10 | ARMAMENT control panel | Set |
| | - WPN type thumbwheel - OFF. |
| | - ATTK MODE knob - MAN. |
| | - DLVY MODE switch - STP. |
| | - DLVY MODE switch - SGL. |
| | - ELECT FUZE knob - Safe. |
| | - A/G GUN switch - OFF. |
| | - MECH FUZE switch - Safe. |
| | - SEL JETT switch - Safe. |
| | - JETT OPTIONS switch - MER TER. |
| | - INTERVAL - Set. |
| | - QTY - Set. |
| | - Station select switches 1 to 8 - Safe. |
| | - MSL OPTIONS switch - NORM. |
| | - MSL SPD GATE knob - NOSE QTR. |
| 11 | Standby attitude gyro | Caged |
| 12 | NAV MODE knob | OFF |
| 13 | Clock | Set and Wind |
| 14 | WCS switch | OFF |
| 15 | IR/TV power switch | OFF |
| 16 | RECORD switch | OFF |
| 17 | RADAR WARNING RCVR PWR switch | OFF |
| 18 | DECM selector knob | OFF |
| 19 | AN/ALE-39 PWR/MODE switch | OFF |
| 20 | DATA LINK ON-OFF-AUX ON switch | OFF |
| 21 | APX-76 | OFF |
| 22 | INTERIOR LIGHTS panel | Check |
| 23 | IFF MASTER knob | OFF |
| 24 | MODE 4 switch | Out |
| 25 | IFF ANT and TEST panel | SET |
| | IFF ANT switch - Off (center). |
| | IND LT-DDI BIT switch - Off (center). |
| | GND CLG switch - OFF. |
| 26 | RADAR BEACON switch | OFF |
| 27 | RADAR BEACON MODE switch | Single or Double |
| 28 | POWER SYS TEST switch | OFF |
| 29 | DATA/ADF switch | OFF |